HIGH-PRESSURE FLOWLINE

Pup Joints

Integral, NPST, threaded or butt-weld pup joints for setting exact high-pressure flowline length and connection orientation.

Request a Quote ↗
Red Pup Joints

PRODUCT OVERVIEW

Purpose and construction

Pup joints are straight pressure-containing sections used between valves, fittings and unions. Integral designs use one-piece forged-ended seamless construction; NPST and other threaded or butt-weld assemblies provide alternative length and maintenance options.

Technical features

  • Integral and NPST construction
  • Butt-weld, integral, LPT-threaded and NPST-threaded ends
  • One-piece forged-alloy-steel integral construction
  • Integral lengths up to 12 ft; threaded/butt-weld lengths up to 20 ft
  • Standard and non-standard lengths
  • Factory-assembled and pressure-tested threaded options
  • MTR and hydrostatic-test documentation when specified

Typical applications

  • Well testing
  • Fracturing and stimulation
  • Cement manifolds
  • Choke and kill lines
  • High-pressure discharge lines

TECHNICAL DATA

Selection and supply basis

Nominal sizeReference ranges include 1 in, 1-1/2 in, 2 in, 3 in and 4 in; configuration dependent
Common high-pressure sizes2 in, 3 in and 4 in
Union figureFig 602, Fig 1002 or Fig 1502
Rated working pressure6,000 to 20,000 psi, construction dependent
LengthIntegral up to 12 ft; threaded/butt-weld up to 20 ft
ConstructionIntegral, NPST, LPT-threaded or butt-weld
ServiceStandard or sour-gas service; final metallurgy and hardness confirmed against the approved fluid data
Temperature basisProject-selected temperature class; reference range -46 °C to 121 °C where stated
InspectionMaterial traceability, dimensional inspection, NDE and hydrostatic/functional testing to the approved ITP
DocumentationDatasheet, drawings, MTRs, NDE and pressure-test records as specified
Supply positioning

Energy Equipment International supplies flowline equipment against approved project requirements. Manufacturing, monogram, certification, interchangeability and performance claims apply only when confirmed in the selected supplier’s approved documentation.

RELATED FLOWLINE PRODUCTS

Complete the pressure line.